Reliable Certified Energy Manager (CEM) Study Materials
For customers who are bearing pressure of work or suffering from career crisis, Certified Energy Manager (CEM) learn tool of inferior quality will be detrimental to their life, render stagnancy or even cause loss of salary. So choosing appropriate CEM test guide is important for you to pass the exam. One thing we are sure, that is our CEM certification material is reliable. With our high-accuracy CEM test guide, our candidates can grasp the key points, and become sophisticated with the exam content. You only need to spend 20-30 hours practicing with our Certified Energy Manager (CEM) learn tool, passing the exam would be a piece of cake.
Fabulous Pass Rate
We attract customers by our fabulous CEM certification material and high pass rate, which are the most powerful evidence to show our strength. We are so proud to tell you that according to the statistics from our customers' feedback, the pass rate among our customers who prepared for the exam with our CEM test guide have reached as high as 99%, which definitely ranks the top among our peers. Hence one can see that the Certified Energy Manager (CEM) learn tool compiled by our company are definitely the best choice for you.
It is believe that employers nowadays are more open to learn new knowledge, as they realize that AEE certification may be conducive to them in refreshing their life, especially in their career arena. A professional AEE certification serves as the most powerful way for you to show your professional knowledge and skills. For those who are struggling for promotion or better job, they should figure out what kind of CEM test guide is most suitable for them. However, some employers are hesitating to choose. We here promise you that our CEM certification material is the best in the market, which can definitely exert positive effect on your study. Our Certified Energy Manager (CEM) learn tool create a kind of relaxing leaning atmosphere that improve the quality as well as the efficiency, on one hand provide conveniences, on the other hand offer great flexibility and mobility for our customers. That's the reason why you should choose us.
Easy Purchase Process
Please don't worry about the purchase process because it's really simple for you. The first step is to select the CEM test guide, choose your favorite version, the contents of different version are the same, but different in their ways of using. The second step: fill in with your email and make sure it is correct, because we send our Certified Energy Manager (CEM) learn tool to you through the email. Later, if there is an update, our system will automatically send you the latest Certified Energy Manager (CEM) version. At the same time, choose the appropriate payment method, such as SWREG, DHpay, etc. Next, enter the payment page, it is noteworthy that we only support credit card payment, do not support debit card. Generally, the system will send the CEM certification material to your mailbox within 10 minutes. If you don't receive it please contact our after-sale service timely.
AEE CEM Exam Syllabus Topics:
| Section | Weight | Objectives |
|---|---|---|
| Lighting Systems | 10% | - Daylighting integration - Lighting technologies and efficiency - Design and control strategies |
| Codes, Standards and Regulations | 5% | - Energy efficiency codes and standards - Compliance and reporting requirements - Sustainability policies and frameworks |
| HVAC Systems and Building Envelope | 15% | - Heating, ventilation and air conditioning - Load calculation and system selection - Thermal envelope performance |
| Distributed Generation and Renewable Energy | 4–6 | - Combined heat and power (CHP) - Solar, wind, biomass, geothermal - Grid integration and economics |
| Boiler and Steam Systems | 4–6 | - Operation and efficiency - Maintenance and optimization |
| Energy Storage Systems | 3–5 | - Integration and benefits - Storage technologies and applications |
| Energy Accounting and Economics | 15% | - Utility rate structures and tariffs - Time value of money, NPV, IRR, payback analysis - Life cycle costing and economic analysis - Energy units and conversions |
| Measurement and Verification | 5% | - Baseline development and savings calculation - M&V protocols and standards |
| Energy Savings Performance Contracting | 5% | - Contract structures and financing - Guaranteed savings and risk allocation |
| Electrical Power Systems and Motors | 15% | - Power distribution and quality - Motor systems, efficiency and controls - Power factor correction and load management |
| Industrial Systems | 6–8 | - Compressed air, pumping, and drying systems - Process energy efficiency |
| Operations, Maintenance and Commissioning | 5% | - Maintenance best practices - Commissioning and retro-commissioning |
| Building Automation and Controls | 5% | - Control systems and strategies - Building management systems - Automation and optimization |
| Energy Audits and Instrumentation | 10% | - Measurement tools and instrumentation - Data collection and analysis - Energy performance indicators - Audit levels and methodologies |
AEE Certified Energy Manager (CEM) Sample Questions:
1. What is the purpose of monitoring energy consumption?
SELECT THE CORRECT ANSWER
A) To support analysis of energy information
B) All of the above
C) To establish a basis of management control
D) To establish when and why there is a deviation in energy consumption patterns
2. A cooling tower delivers water to a chilled-water plant at 21°C. The outside ambient air conditions are 19°C dry bulb, 50% relative humidity. Using the psychrometric chart, what is the approach temperature of the cooling tower outlet water temperature to the ambient air wet-bulb temperature?
SELECT THE CORRECT ANSWER
A) 4°C
B) 8°C
C) 10°C
D) 6°C
3. In a performance contract, which group has the greatest investment risk?
A) Risk is shared by the terms in the performance contract
B) The energy-service company
C) The company installing the energy project
D) The equipment manufacturer
4. A concentrating solar thermal system collects 5 GJ/h of thermal heat, which is delivered to a 94% efficient hot water generator. The hot water generator is used to raise the water temperature from 15°C to 65°C. The specific heat of water (Cp) is 4.2 kJ/kg-°C. What flow rate (liter/second) of hot water can be delivered from the hot water generator?
A) 6.2 liter/second
B) 12.0 liter/second
C) 9.2 liter/second
D) 4.2 liter/second
5. Using an interest rate of 15%, an energy project has a net-present value (NPV) of $3,500. Which statement is true about the project's internal rate of return (IRR)?
A) IRR < 15%
B) IRR > 15%
C) IRR = 15%
D) IRR < 0%
Solutions:
| Question # 1 Answer: B | Question # 2 Answer: B | Question # 3 Answer: B | Question # 4 Answer: C | Question # 5 Answer: B |

978 Customer Reviews 







Eric -
I am very interested in this CEM course and i also have a brandnew study experience! The most improtant thing is that i have passed my CEM exam! Thank you!